Ico printer

KSPKV

Serial production list

Contact water-and-splash proof position signaling device

Technical characteristics:

Signaling devices KSPKV

Drive element

Rod

Rod shift, mm  
  • working;  
  • differential;  
  • additional (after direct response of contacts).

4±0.6 0.3 1.5

Rod shift speed, mm/s

1-300

Number of commutated circuits

2

Parameters of commutated circuits:  
  • direct current (at voltage);  
  • alternating current (at voltage).

 

0.001-1А (3-48V)

0.02-1А (15-220V)

Signaling devices KSPKV are intended for monitoring position of moving units of mechanisms and fittings which are kinematically linked with signaling devices’ rod  

Ambient temperature (air,water), °С   

    • permanently;  
  • for no longer than 4 hours;

0 - +50 +50 - +120

Pressure, MPa:

    • permanently;  
  • for no longer than 4 hours;

0.08 – 0.22 1.47

Humidity up to, %

100

Weight, kg, maximum

2.0

 

Versions of signaling device KSPKV:
Version Number of positions to be fixed Features of rod structure
Connection elements Initial position

KSPKV-2b  
KSPKV-2bk  

2

Ball

Moved out

KSPKV-3а

KSPKV-3а1  

3

Thread М6

Medium

KSPKV-3v
KSPKV-3v1  

3

Loose-rotating link

Medium

Overall and mounting dimensions:
Overall and mounting dimensions KSPKV Version a b c d e f
KSPKV-2b   175 135 60 30 6.5 37
KSPKV-2bk   175 135 60 10 6.5 37

KSPKV-3а

 
175 135 60 30 6.5 37

KSPKV-3а1

190 135 60 15 6.5 37
KSPKV-3v 175 135 60 45 6.5 37
KSPKV-3v1 190 135 60 30 6.5 37
KSPKV condition checking device

Condition checking device (PKP) is intended for checking the signaling device KSPKV for good condition, as well as for integrity checking of external electric circuits which are temporarily disconnected from the signaling device

Version Devices to be monitored
PKP-2 KSPKV-2b, KSPKV-2bk
PKP-3 KSPKV-3а, KSPKV-3v, KSPKV-3а1, KSPKV-3v1











 

Price, delivery terms and period are provided on request

 